Research Paper

Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging

ZhiNing Zhang, Min Zhao, Bin Chen, YiMing Cao, Shi Gao

Department of Nuclear Medicine, China-Japan Union Hospital of Jilin University, Changchun 130033, China.

Citation:
Zhang Z, Zhao M, Chen B, Cao Y, Gao S. Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging. J Cancer 2024; 15(7):1863-1869. doi:10.7150/jca.91483. https://www.jcancer.org/v15p1863.htm
Other styles

File import instruction

Abstract

Graphic abstract

Objective: To compare the diagnostic efficacy of 11C-choline PET/CT, neck ultrasonography, 99mTc-MIBI dual-phase planar scintigraphy, and 99mTc-MIBI SPECT/CT imaging in the diagnosis of primary hyperparathyroidism (PHPT).

Methods: We conducted a retrospective analysis of 32 patients with PHPT who visited the Nuclear Medicine Department of Jilin University China-Japan Union Hospital between January 2019 and December 2022. All patients underwent 11C-choline PET/CT, neck ultrasonography, 99mTc-MIBI dual-phase planar scintigraphy, and 99mTc-MIBI SPECT/CT examinations within two months before surgery. Sensitivity, specificity, positive predictive value, and negative predictive value of each imaging study were compared using postoperative pathology and follow-up results. Diagnostic efficacy was further analyzed using ROC curve analysis. Factors influencing on 99mTc-MIBI imaging were also investigated.

Results: A total of 35 lesions were resected in the 32 patients. The diagnostic sensitivity of 11C-choline PET/CT, neck ultrasonography, 99mTc-MIBI dual-phase planar scintigraphy, and 99mTc-MIBI SPECT/CT was 88.2%, 52.9%, 58.8%, and 67.6%, respectively. Specificity was 96.8%, 95.7%, 96.8%, and 95.7%, respectively. Positive predictive values were 90.9%, 81.8%, 86.9%, and 85.2%, respectively, and negative predictive values were 95.7%, 84.9%, 86.7%, and 89.1%, respectively. The areas under the ROC curve (AUC) were 0.925, 0.743, 0.778, and 0.817, respectively. Among them, 11C-choline PET/CT had higher sensitivity and AUC than other imaging studies (p<0.05), while specificity, positive predictive value, and negative predictive value were similar (p>0.05). The positive group in 99mTc-MIBI SPECT/CT imaging had significantly larger lesion diameters than the negative group (P<0.05), while preoperative blood calcium and PTH showed no statistical differences (P>0.05).

Conclusion: 11C-choline PET/CT demonstrates superior preoperative diagnostic efficacy for PHPT compared to neck ultrasonography, 99mTc-MIBI dual-phase planar scintigraphy, and 99mTc-MIBI SPECT/CT. Lesion size may be the primary factor affecting the sensitivity of 99mTc-MIBI imaging.

Keywords: primary hyperparathyroidism, 11C-choline, 99mTc-MIBI, neck ultrasonography, SPECT, PET


Citation styles

APA
Zhang, Z., Zhao, M., Chen, B., Cao, Y., Gao, S. (2024). Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging. Journal of Cancer, 15(7), 1863-1869. https://doi.org/10.7150/jca.91483.

ACS
Zhang, Z.; Zhao, M.; Chen, B.; Cao, Y.; Gao, S. Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging. J. Cancer 2024, 15 (7), 1863-1869. DOI: 10.7150/jca.91483.

NLM
Zhang Z, Zhao M, Chen B, Cao Y, Gao S. Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging. J Cancer 2024; 15(7):1863-1869. doi:10.7150/jca.91483. https://www.jcancer.org/v15p1863.htm

CSE
Zhang Z, Zhao M, Chen B, Cao Y, Gao S. 2024. Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging. J Cancer. 15(7):1863-1869.

This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/). See http://ivyspring.com/terms for full terms and conditions.
Popup Image